Skip to main content
IS 1888:1982 · load–settlement interpretation

Plate load test calculation (IS 1888)

Interprets a plate load test per IS 1888:1982: zero correction, ultimate pressure from the log-log plot, safe pressure, modulus of subgrade reaction and the settlement of the full-size footing.

Free · no signup · computed in your browser by the engine TerraBrains runs in the app.

Inputs

Illustrative inputs are loaded to demonstrate the method. Replace them with your measured project data before interpreting results. The readings are the signed-in page’s illustrative set (IS 1888 itself contains no worked example) — replace them with your test’s first-loading readings.

Keep this calculation

Free here. In TerraBrains this result is saved to the project, carries its clause into a signed report your client can verify, and updates when the borehole does.

Log the borehole this came from — the TerraBrains field app on iPhone, iPad and Android works offline on site and syncs the SPT, samples and layers to the same project.

Worked examples — checked live

Each example comes from a published source. Its inputs run through the same engine as your calculation above; a ✓ means our value is inside the tolerance stated for that example. Load one to see it in the form.

600 mm plate on sand — pressure for 25 mm settlement of a 1.5 m footing (IS 1888 Cl 5.3)

Source: Structville, "How to Determine the Bearing Capacity of Soils from Plate Load Test" (Mar 2021) — S_p = 16 mm for S_f = 25 mm; pressure at 16 mm ≈ 290 kPa (read off the curve)

1/1 within tolerance

IS 1888 Cl 5.3 / Terzaghi–Peck: S_p = S_f·[B_p(B + 0.3)/(B(B_p + 0.3))]² = 25 × [0.6 × 1.8/(1.5 × 0.9)]² = 16 mm.

QuantityPublishedOursΔWithin tolerance
Pressure at the plate settlement equivalent to 25 mm under the footing (kPa)290.0285.71.48 %✓

Tolerance: ±2 % (The source reads 290 kPa off a drawn curve; the engine interpolates linearly between the 200 kPa (10 mm) and 300 kPa (17 mm) readings (285.7 kPa).)

Questions engineers ask

How is the ultimate pressure picked from the readings?

From the intersection of the two straight lines on the log-log load–settlement plot, the IS 1888 method. If the curve has no clear break, a yield point is used; if neither exists, the maximum applied pressure is reported as a lower bound and labelled as such.

How is the plate result scaled to the real footing?

For cohesionless soil the settlement is scaled with the B/Bp law S_f = S_p·[B(Bp + 0.3)/(Bp(B + 0.3))]², and the ultimate pressure with B/Bp. For cohesive soil settlement scales with B/Bp and the ultimate pressure is taken equal to the plate’s.

What is the modulus of subgrade reaction here?

k = the plate pressure at 1.25 mm settlement ÷ 1.25 mm (IS 9214:1979 Cl 2.3, K = p/0.00125), reported in MPa/m for the plate size tested.

Where does the 25 mm permissible settlement come from?

It is the IS 1904:1986 Cl 4.1 value for isolated footings and is only a default — enter your project’s permissible settlement and the pressure at that settlement is recomputed.

All ten calculators

Save it, sign it, keep it current.

A free account saves the result to a project with its PDF calculation sheet, and carries the clause into a signed report your client can verify. The same engines run 233 analyses and 47 lab tests inside. 14 days free, no card.