Skip to main content
EN 1997-1 · AASHTO LRFD · BS 8004 · IS 6403

Bearing capacity calculator

Ultimate, net safe and allowable bearing pressure of a shallow footing — IS 6403:1981 general shear equation with shape, depth, inclination and water-table factors, or the Eurocode 7 / AASHTO / BS 8004 design resistance.

Free · no signup · computed in your browser by the engine TerraBrains runs in the app.

Inputs

Illustrative inputs are loaded to demonstrate the method. Replace them with your measured project data before interpreting results.

Keep this calculation

Free here. In TerraBrains this result is saved to the project, carries its clause into a signed report your client can verify, and updates when the borehole does.

Log the borehole this came from — the TerraBrains field app on iPhone, iPad and Android works offline on site and syncs the SPT, samples and layers to the same project.

Worked examples — checked live

Each example comes from a published source. Its inputs run through the same engine as your calculation above; a ✓ means our value is inside the tolerance stated for that example. Load one to see it in the form.

IS 6403 — 23.8 m circular tank on saturated clay (φ = 0)

Source: Mittal, S., Pile Foundation Design and Construction (incl. Well Foundation), 3rd ed., CBS Publishers — Example 6.6, Eqs. 6.12–6.13 (IS 6403:1981)

4/4 within tolerance

The book takes the tank as founded at ground level (dc = 1, ic = 1), so Df = 0. c = 2.7 t/m² is entered as 26.48 kPa. The book gives only the submerged unit weight γ′ = 0.95 t/m³ (9.32 kN/m³); the bulk box takes γsat = γ′ + γw = 19.13 kN/m³. Neither changes a φ = 0 surface footing (Nγ = 0, q = 0). The answer is the NET value — compare it with qnu, not qult (equal here only because Df = 0).

QuantityPublishedOursΔWithin tolerance
Net ultimate bearing capacity qd = c·Nc·sc·dc·ic (kPa)176.9176.90.01 %✓
Safe bearing capacity qd / FoS (FoS 2.5) (kPa)70.7170.770.09 %✓
Nc (IS 6403 Table 1, φ = 0)5.1405.1400.00 %✓
Shape factor sc (circle, IS 6403 Table 2)1.3001.3000.00 %✓

Tolerance: ±0.5 % (Source prints 18.04 t/m² (4 s.f.); converted exactly at 9.80665 kPa per t/m².) · ±0.5 % (Source prints 7.21 t/m² (18.04/2.5 = 7.216, truncated to 2 dp).) · ±0.1 % (Printed to 3 s.f.; the engine uses the π + 2 limit printed as 5.14.) · ±0.01 % (Exact tabulated value.)

Questions engineers ask

Which bearing capacity factors does the IS 6403 method use?

Nc (Prandtl) and Nq (Reissner) in their closed forms, and Vesic’s Nγ as the IS 6403:1981 note permits. Depth factors follow Cl 5.1.2.2 and the load-inclination factors Cl 5.1.2.3: ic = iq = (1 − α/90)², iγ = (1 − α/φ)². Every factor used is listed under the result.

What is the difference between qult, qns and qa here?

qult is the gross ultimate capacity. The net ultimate qnu = qult − q (IS 6403 deducts the factored surcharge q·sq·dq·iq·Rw1), the net safe bearing capacity qns = qnu ÷ FoS (IS 6403:1981 Cl 6.1(a), which leaves the factor of safety to the engineer — 3.0 is only the default here), and the allowable gross pressure qa = qns + q. qns is also shown in t/m² for Indian reports. FoS is used for IS 6403 and BS 8004 only; Eurocode 7 and AASHTO apply their own partial or resistance factors instead.

How is a high water table handled?

Leave the water-table depth blank for a deep water table. When you enter it, the surcharge and self-weight terms are reduced with the water-table reduction factors Rw1 and Rw2, which are reported with the other factors.

Can I check an eccentric or inclined load?

Yes. Eccentricities e_B and e_L use the Meyerhof effective-area method (B′ = B − 2e_B), and a load inclination α from the vertical applies the IS 6403 inclination factors. Ground-slope factors are available for the Hansen and Vesic methods, and base-tilt factors for Hansen, Vesic and EN 1997-1 Annex D; IS 6403 has neither.

All ten calculators

Save it, sign it, keep it current.

A free account saves the result to a project with its PDF calculation sheet, and carries the clause into a signed report your client can verify. The same engines run 233 analyses and 47 lab tests inside. 14 days free, no card.