Boulanger-Idriss 2014 · NCEER / Youd 2001 · IS 1893-1:2016 Annex F
Liquefaction calculator — SPT-based triggering
Factor of safety against liquefaction at every SPT depth — CSR against CRR by Boulanger & Idriss (2014), the IS 1893 (Part 1):2016 Annex F NCEER procedure or Cetin et al., with fines, Kσ and magnitude scaling.
Free · no signup · computed in your browser by the engine TerraBrains runs in the app.
Scroll across the table for units, typical values and standards.
Symbol
Full form
Unit
Typical / standard value
Standard
CSR
Cyclic stress ratioEarthquake-induced cyclic shear stress ÷ effective overburden — the demand in liquefaction triggering.
—
—
—
CRR
Cyclic resistance ratioThe soil's resistance to liquefaction from SPT/CPT/Vs correlations — the capacity side.
—
—
—
FS_liq
Factor of safety against liquefactionCRR ÷ CSR; < 1 means liquefaction is triggered at that depth.
—
<1 triggers · ≥1.25 typically safe
—
(N₁)₆₀
Corrected SPT NN₆₀ further normalised to 1 atm overburden — used in liquefaction and capacity correlations.
blows/300mm
—
—
σ′_v
Effective vertical stressOverburden pressure minus pore-water pressure at a depth.
kPa
—
—
k_h
Horizontal seismic coefficientPseudo-static horizontal acceleration as a fraction of g.
—
≈ 0.5·PGA/g (Hynes-Griffin & Franklin)
IS 1893
V_s
Shear-wave velocitySpeed of shear waves — a direct measure of small-strain stiffness (Gmax = ρ·Vs²).
m/s
—
—
S
SettlementVertical downward movement of the foundation under load — immediate + consolidation + secondary.
mm
—
—
FoS
Factor of safetyResisting capacity ÷ applied demand. The margin against failure.
—
bearing ≥3 · slopes ≥1.3–1.5 · sliding ≥1.5
—
Tap any unit to convert from it. Unit weight ↔ density uses g = 9.80665 m/s² (γ = ρg).
Inputs
Illustrative inputs are loaded to demonstrate the method. Replace them with your measured project data before interpreting results.
Keep this calculation
Free here. In TerraBrains this result is saved to the project, carries its clause into a signed report your client can verify, and updates when the borehole does.
Log the borehole this came from — the TerraBrains field app on iPhone, iPad and Android works offline on site and syncs the SPT, samples and layers to the same project.
Worked examples — checked live
Each example comes from a published source. Its inputs run through the same engine as your calculation above; a ✓ means our value is inside the tolerance stated for that example. Load one to see it in the form.
Idriss & Boulanger (2008) single-boring example — M 6.9, a_max 0.28 g
Source: Idriss, I.M. & Boulanger, R.W., Soil Liquefaction During Earthquakes, EERI Monograph MNO-12 (2008), Appendix A spreadsheet (pp. 238–239)
9/9 within tolerance
Hammer energy ratio 75 %; rod length left to the engine default (depth + 1.5 m, Youd et al. 2001), which is what the spreadsheet does. The CH rows (PI 30) and the dry 1.1 m row are reported non-susceptible. FS is not compared — see the file header.
Tolerance: ±0.85 % (CGM-10 Table 3.1 gives σv and σ′v, not unit weights; a uniform γ = σv/z reproduces σv exactly and σ′v within ≈1 kPa ⇒ ±0.2 blow.) · ±3.26 % (Same σ′v reconstruction (±1 kPa) ⇒ ±0.006 on CSR printed to 2–3 dp.)
IS 1893 Annex F — magnitude scaling factor at Mw 7.0
Source: IS 1893 (Part 1):2016 Annex F Step 5 (MSF = 10^2.24 / Mw^2.56), tabulated in Youd et al. (2001) J. Geotech. Geoenviron. Eng. 127(10), Table 3 "Idriss" column — MSF(7.0) = 1.19
1/1 within tolerance
IS 1893 prints the MSF expression but no worked example; Youd et al. (2001) Table 3 tabulates the same expression.
Quantity
Published
Ours
Δ
Within tolerance
MSF (Mw 7.0)
1.190
1.193
0.23 %
✓
Tolerance: ±1.3 % (Table printed to 2 dp (and truncated, not rounded).)
Questions engineers ask
When is a layer reported as liquefiable?
+
When its factor of safety FoS = CRR·MSF·Kσ / CSR is below 1.0. Layers between 1.0 and your minimum acceptable FoS (1.2 by default, IS 1893-1:2016 Annex F) are reported as marginal.
Are clayey layers checked?
+
A layer with a plasticity index of 7 or more is reported as non-susceptible (Bray & Sancio 2006) rather than given a factor of safety. Leave PI blank for clean or non-plastic sands.
What PGA should I enter?
+
The design peak ground acceleration in g. The zone picker fills the IS 1893-1:2016 zone factor Z (II 0.10, III 0.16, IV 0.24, V 0.36); replace it with a site-specific value if you have one.
How are energy and rod corrections handled?
+
Enter the hammer energy ratio ERᵣ for a row to correct it to N₆₀ (CE = ERᵣ/60). A blank ERᵣ means the blow count is already N₆₀ (CE = 1.0). Borehole and sampler corrections CB and CS default to 1.0.
A free account saves the result to a project with its PDF calculation sheet, and carries the clause into a signed report your client can verify. The same engines run 233 analyses and 47 lab tests inside. 14 days free, no card.