Skip to main content
EN 1997-1 · AASHTO LRFD · Mononobe-Okabe · IS 14458

Earth pressure calculator — Rankine and Coulomb

Active, passive and at-rest earth pressure coefficients and thrusts on a retaining wall — Rankine or Coulomb per IS 14458 (Part 1):1998 Cl 5.1/5.2, with surcharge, water, the Eurocode 7 / AASHTO design thrust and optional Mononobe-Okabe seismic.

Free · no signup · computed in your browser by the engine TerraBrains runs in the app.

Inputs

Illustrative inputs are loaded to demonstrate the method. Replace them with your measured project data before interpreting results.

Keep this calculation

Free here. In TerraBrains this result is saved to the project, carries its clause into a signed report your client can verify, and updates when the borehole does.

Log the borehole this came from — the TerraBrains field app on iPhone, iPad and Android works offline on site and syncs the SPT, samples and layers to the same project.

Worked examples — checked live

Each example comes from a published source. Its inputs run through the same engine as your calculation above; a ✓ means our value is inside the tolerance stated for that example. Load one to see it in the form.

At-rest thrust on a 5 m wall with the water table at 2.5 m

Source: Das, B.M., Principles of Foundation Engineering (Cengage), Example 12.1 — K0 = 0.5, P0 = 122.85 kN/m at 1.53 m above the base

3/3 within tolerance
QuantityPublishedOursΔWithin tolerance
K0 = 1 − sin φ′ (Jaky)0.50000.50000.00 %✓
At-rest thrust P0 (soil + water) (kN/m)122.8122.80.02 %✓
Line of action above the base (m)1.5301.5330.20 %✓

Tolerance: ±0.1 % (Exact at φ′ = 30°.) · ±0.5 % (Printed to 2 dp; Das uses γw = 9.81.) · ±1.5 % (Printed to 2 dp (±0.005 m on a moment ratio).)

Questions engineers ask

When should I use Coulomb instead of Rankine?

Rankine assumes a smooth vertical wall. Coulomb includes wall friction δ and a wall inclination α, so use it when the back of the wall is battered or rough. The method is independent of the design code you pick.

How is a cohesive backfill treated?

The tension-crack depth z_c is reported and the headline active thrust neglects the tension zone above it (IS 14458 Cl 5.1.2). The net-area and crack-filled conventions are shown alongside so you can choose.

What do the Eurocode 7 and AASHTO options change?

They apply that code’s factors. EC7 DA1-C2 and DA3 factor the soil strength (φ′d, c′d) before Ka and Kp are computed; DA1-C1 and DA2 factor the actions; AASHTO LRFD applies the load factor γEH. The design thrust and every factor used are reported.

How is seismic earth pressure computed?

Switch on Mononobe-Okabe and enter kh (kv defaults to ⅔·kh). The calculator reports Kae, Kpe, the total seismic active thrust Pae = ½γH²(1 − kv)Kae and the dynamic increment ΔPae.

All ten calculators

Save it, sign it, keep it current.

A free account saves the result to a project with its PDF calculation sheet, and carries the clause into a signed report your client can verify. The same engines run 233 analyses and 47 lab tests inside. 14 days free, no card.