Skip to main content
ASTM D4318 · BS 1377-2 · ASTM D2487 · IS 2720 (Part 5)

Atterberg limits calculator — LL, PL and PI

Liquid limit from the Casagrande flow curve at 25 blows (ASTM D4318) or the cone penetrometer at 20 mm (IS 2720-5), plastic limit, plasticity index and the USCS fine-grained group from the plasticity chart.

Free · no signup · computed in your browser by the engine TerraBrains runs in the app.

Inputs

Illustrative inputs are loaded to demonstrate the method. Replace them with your measured project data before interpreting results. These trials are the lab form’s “e.g.” placeholders — replace them with your measurements. Enter each moisture content directly, or the three weighings and w is reduced from them (IS 2720-2 / ASTM D2216).

Keep this calculation

Free here. In TerraBrains this result is saved to the project, carries its clause into a signed report your client can verify, and updates when the borehole does.

Log the borehole this came from — the TerraBrains field app on iPhone, iPad and Android works offline on site and syncs the SPT, samples and layers to the same project.

Worked examples — checked live

Each example comes from a published source. Its inputs run through the same engine as your calculation above; a ✓ means our value is inside the tolerance stated for that example. Load one to see it in the form.

Fall-cone liquid limit (80 g / 30° cone, LL at 20 mm) and plastic limit — clay of intermediate plasticity

Source: Craig's Soil Mechanics, 8th ed. (Knappett & Craig), Example 1.1, soil D and Fig. 1.14 — LL = 42 %, PL = 24 %, PI = 18 %

3/3 within tolerance

The cone method is the one IS 2720 (Part 5):1985 Cl 4 and BS 1377-2 specify (LL at 20 mm penetration). Craig classifies the soil CI on the BS/IS plasticity chart; the calculator's symbol is USCS (CL), which has no intermediate band.

QuantityPublishedOursΔWithin tolerance
Liquid limit (w at 20 mm penetration) (%)42.0042.481.14 %✓
Plastic limit (mean of two trials) (%)24.0024.100.42 %✓
Plasticity index LL − PL (%)18.0018.382.11 %✓

Tolerance: ±1.19 % (Craig reports LL to the nearest whole number (±0.5 % points); the engine gives 42.48 unrounded.) · ±2.1 % (Reported to the nearest whole number (±0.5); the mean is 24.1.) · ±5.6 % (Difference of two whole-number values, each ±0.5 ⇒ ±1 on 18.)

Questions engineers ask

How is the liquid limit read from my trials?

Casagrande cup: a straight line is fitted to moisture content against log₁₀(blows) through all trials and read at 25 blows (ASTM D4318). Cone: moisture content against penetration is fitted linearly and read at 20 mm (IS 2720-5). At least two trials are needed.

What happens if the plastic limit is above the liquid limit?

The soil is reported non-plastic (NP), as ASTM D4318 requires, and the plasticity index is recorded as zero, as IS 2720-5 does — never as a negative number.

How is the USCS group decided?

From ASTM D2487 Fig. 4: below LL 50, a soil on or above the A-line with PI > 7 is CL, 4 ≤ PI ≤ 7 is CL-ML, otherwise ML; at LL 50 or more it is CH above the A-line and MH below. A point above the U-line is flagged for re-checking.

All ten calculators

Save it, sign it, keep it current.

A free account saves the result to a project with its PDF calculation sheet, and carries the clause into a signed report your client can verify. The same engines run 233 analyses and 47 lab tests inside. 14 days free, no card.